Your browser doesn't support javascript.
loading
Successful coronary stent retrieval from the ascending aorta using a gooseneck snare kit
The Korean Journal of Internal Medicine ; : 481-485, 2013.
Article Dans Anglais | WPRIM | ID: wpr-212575
ABSTRACT
Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a case of stent dislodgement in the ascending thoracic aorta. The stent was mechanically distorted in the left circumflex artery (LCX) while being delivered to the proximal LCX lesion. The balloon catheter was withdrawn, but the stent with the guide wire was remained in the ascending thoracic aorta. The stent was unable to be retrieved into the guide catheter, as it was distorted. A goose neck snare was used successfully to catch the stent in the ascending thoracic aorta and retrieved the stent externally via the arterial sheath.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Aorte thoracique / Cathétérisme cardiaque / Angioplastie coronaire par ballonnet / Radiographie interventionnelle / Endoprothèses / Résultat thérapeutique / Coronarographie / Ablation de dispositif / Corps étrangers Limites du sujet: Humains / Mâle langue: Anglais Texte intégral: The Korean Journal of Internal Medicine Année: 2013 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Aorte thoracique / Cathétérisme cardiaque / Angioplastie coronaire par ballonnet / Radiographie interventionnelle / Endoprothèses / Résultat thérapeutique / Coronarographie / Ablation de dispositif / Corps étrangers Limites du sujet: Humains / Mâle langue: Anglais Texte intégral: The Korean Journal of Internal Medicine Année: 2013 Type: Article