Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 291-294, 2017.
Article Dans Anglais | WPRIM | ID: wpr-217609
ABSTRACT
A 74-year-old patient presented with recurrent aneurysms in the infrarenal abdominal aorta and right common iliac artery 6 years after endovascular aortic repair using endografts in the same location. The patient underwent an aorto-bi-iliac replacement with removal of the stent graft. Two holes measuring 2 mm each were found in the removed graft, and they appeared to have been caused by wear from continuous friction between the endograft and the aortic wall.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Aorte / Aorte abdominale / Prothèse vasculaire / Friction / Anévrysme de l'aorte abdominale / Transplants / Endofuite / Procédures endovasculaires / Artère iliaque / Anévrysme Limites du sujet: Adulte très âgé / Humains langue: Anglais Texte intégral: The Korean Journal of Thoracic and Cardiovascular Surgery Année: 2017 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Aorte / Aorte abdominale / Prothèse vasculaire / Friction / Anévrysme de l'aorte abdominale / Transplants / Endofuite / Procédures endovasculaires / Artère iliaque / Anévrysme Limites du sujet: Adulte très âgé / Humains langue: Anglais Texte intégral: The Korean Journal of Thoracic and Cardiovascular Surgery Année: 2017 Type: Article