PURPOSE:
To assess the usefulness of the Hounsfield number, measured by a non-contrast enhanced pelvic CT, after a uterine artery embolization as an index of the successful outcome of a uterine fibroid embolization (UFE). MATERIALS ANDMETHODS:
The study subjects included 15 women (age range 28-49 years, mean age 36.4 years) diagnosed with symptomatic uterine myomas and seen from March 2003 to August 2005. A non-contrast enhanced pelvic CT scan was performed six hours after a uterine artery embolization. The global and maximal CT numbers were measured for each myoma. In addition, a pelvic MRI was performed to measure the volume of each myoma prior to and 6 months after the UFE. The relationship between fibroid volume reduction and the global CT number were prospectively analysed.RESULTS:
The mean global CT number was 91.25 HU in Group I and 40.8 HU in Group II. Further, the mean fibroid volume reduction rate was 73% in Group I and 10% in Group II (p < 0.05).CONCLUSION:
The global CT number measured by a non-contrast enhanced pelvic CT is a useful predictive factor of a successful uterine fibroid embolization.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Tumeurs de l'utérus
/
Tomodensitométrie
/
Radiologie interventionnelle
/
Études prospectives
/
Embolisation thérapeutique
/
Embolisation d'artère utérine
/
Léiomyome
/
Myome
Type d'étude:
Étude observationnelle
/
Étude pronostique
Limites du sujet:
Femelle
/
Humains
langue:
Coréen
Texte intégral:
Journal of the Korean Radiological Society
Année:
2008
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS