Research on calculation of the regional cerebral blood volume based on minimum mean square error method / 生物医学工程学杂志
Journal of Biomedical Engineering ; (6): 1207-1211, 2014.
Article Dans Chinois | WPRIM | ID: wpr-234429
ABSTRACT
In this paper, the Fourier transform based minimum mean square error (FT-based MMSE) method is used to calculate the regional cerebral blood volume (rCBV) in magnetic resonance (MR) perfusion imaging, and the method is improved to handle the existing noise in the imaging process. In the experiments with signal-to-noise ratio (SNR) of 50 dB, the rCBV values were compared with the results using MMSE method. The effects of different SNRs on the estimation of rCBV were analyzed. The experimental results showed that MMSE was a simple way to filter the measurement noise, and could calculate rCBV accurately. Compared with other existing methods, the present method is not sensitive to environment, and furthermore, it is suitable to deal with the perfusion images acquired from the environment with larger SNR.
Sujets)
Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Volume sanguin / Encéphale / Angiographie par résonance magnétique / Analyse de Fourier Limites du sujet: Humains langue: Chinois Texte intégral: Journal of Biomedical Engineering Année: 2014 Type: Article