Your browser doesn't support javascript.
loading
Hybrid Technique to Correct Cerebral Malperfusion Following Repair of a Type A Aortic Dissection
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 163-166, 2014.
Article Dans Anglais | WPRIM | ID: wpr-24182
ABSTRACT
A 49-year-old man with drowsy mentality was diagnosed with acute type A aortic dissection; he underwent an emergency operation. When selective antegrade cerebral perfusion was initiated, the right regional cerebral oxygen saturation (rSO2) decreased as compared to the left one. Adequate blood flow was perfused through the branch of the artificial graft, after distal anastomosis, but the right rSO2 did not recover. Angiography revealed another intimal tear on the right common carotid artery. A stent was then inserted. The right rSO2 promptly increased to the same level as that of the left one. The patient was discharged without any neurologic complications.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Oxygène / Perfusion / Angiographie cérébrale / Angiographie / Endoprothèses / Artère carotide commune / Transplants / Urgences Limites du sujet: Humains langue: Anglais Texte intégral: The Korean Journal of Thoracic and Cardiovascular Surgery Année: 2014 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Oxygène / Perfusion / Angiographie cérébrale / Angiographie / Endoprothèses / Artère carotide commune / Transplants / Urgences Limites du sujet: Humains langue: Anglais Texte intégral: The Korean Journal of Thoracic and Cardiovascular Surgery Année: 2014 Type: Article