Application of GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy to prevent peristomal hernia / 中华胃肠外科杂志
Chinese Journal of Gastrointestinal Surgery
;
(12): 480-482, 2009.
Article
Dans Chinois
| WPRIM
| ID: wpr-259385
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the effect of GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy on the prevention of peristomal hernia.</p><p><b>METHODS</b>Sixty patients undergone sigmoid-colostomy from Jan. 2003 to Jan. 2005 in the first affiliated hospital of Sun Yat-sen University were selected and randomly divided into two groups. Patients received papillary sigmoid-colostomy through rectus abdominis and peritoneum in control group and GORE-TEX Dual Mesh fixing into peritoneum during sigmoid-colostomy in observation group. Complications and recurrence rate were recorded in follow-up period.</p><p><b>RESULTS</b>Peristomal hernia occurred in eight patients (8/30) in control group (26.7%), while no hernia happened in observation group (0/30).</p><p><b>CONCLUSION</b>GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy can prevent peristomal hernia.</p>