Your browser doesn't support javascript.
loading
A three-dimensional finite element analysis of stress distribution in mandibular FPDs with different length pontics / 中华口腔医学杂志
Chinese Journal of Stomatology ; (12): 133-135, 2004.
Article Dans Chinois | WPRIM | ID: wpr-263438
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the stress distribution in the mandibular fixed partial denture (FPD) by changing the length of pontics.</p><p><b>METHODS</b>Based on a 3-DFE model of the mandibular FPD, we analyzed the stress distribution in the mandibular FPDs by loading the same level force at pontics with different lengths that were 2 to 4 times of normal length.</p><p><b>RESULTS</b>The distribution trends of the stresses in the mandibular FPDs with differently elongated pontics were similar, but the highest von Mises stress in the bridge was enlarged.</p><p><b>CONCLUSION</b>Damages may develop in the mandibular FDP, when the length of the pontic is longer than 3 times of normal length.</p>
Sujets)
Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Analyse des éléments finis / Analyse du stress dentaire / Prothèse partielle fixe / Mandibule Limites du sujet: Humains langue: Chinois Texte intégral: Chinese Journal of Stomatology Année: 2004 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS