A cadaveric study on establishing an individualized navigation template for the placement of occipital condyle screws using a three-dimensional printing technique / 中华外科杂志
Chinese Journal of Surgery
;
(12): 523-528, 2014.
Article
Dans Chinois
| WPRIM
| ID: wpr-314676
ABSTRACT
<p><b>OBJECTIVES</b>To investigate the feasibility of establishing an individualized navigation template for occipital condyle screws insertion using a fused deposition modeling based three-dimensional printing forming technique, and to evaluate the accuracy and safety of template-assisted condyle screw insertion.</p><p><b>METHODS</b>Thirty adult occipitocervical specimens were selected to take a CT-scan. After original Dicom data imported into the Mimics software, the craniocervical junction models were created, which were used to evaluate anatomic structures and define the screw-related parameters. Design and generate the cavity models of the occipital condyle based on a three-dimensional printing forming technique. After using a free-hand procedure to create a navigation template with a well-established screw path, finish bilateral condyle screws insertion assisted by the navigation template. Anatomy study and CT-scan were taken postoperatively to access the position of the screws.</p><p><b>RESULTS</b>Sixty condyle screws were implanted assisted by 30 individualized navigation templates with an average time cost of (91.4 ± 8.2) s. The axial medial angle, sagittal cranial angle and distance between the entry point to atlantooccipital joint surface were (33.2 ± 6.4)°, (8.9 ± 3.4)°, (3.9 ± 0.9) mm, respectively. The variations due to different sex and sides resulted in a statistically insignificant difference of the parameters. Anatomy study and CT-scan indicated no intrusion of the vertebral artery, hypoglossal canal, condyle emissary vein canal or atlantooccipital joint. Fifty-nine condyle screws were completely contained within the condyle, while only 1 screw perforated lateral condyle wall.</p><p><b>CONCLUSIONS</b>Using the Mimics software for establishing the occipital condyle and related cavity model based on CT-scan images proves to be a feasible and precise method.Occipital condyle screws insertion assisted by a three-dimensional printing model is highly accurate and simple, which could be a new alternative to conventional technique.</p>
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Chirurgie générale
/
Vis orthopédiques
/
Cadavre
/
Chirurgie assistée par ordinateur
/
Impression tridimensionnelle
/
Os occipital
Limites du sujet:
Adulte
/
Adulte très âgé
/
Femelle
/
Humains
/
Mâle
langue:
Chinois
Texte intégral:
Chinese Journal of Surgery
Année:
2014
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS