Spontaneous urinary voiding of metallic screws in a patient with symphyseal plating for type II pelvic ring disruption / 中华创伤杂志(英文版)
Chinese Journal of Traumatology
;
(6): 230-232, 2013.
Article
Dans Anglais
| WPRIM
| ID: wpr-325704
ABSTRACT
With rapid advancement in surgical techniques and improvement in implant materials, rate of internal fixation for pubic symphyseal disruption in rotationally and vertically unstable pelvic ring injuries has increased. Among various modes of implant failure, screw/plate breakage and loosening are common complications following unstable fixation. Migration of loose screws into the urinary bladder has been reported as an extremely uncommon complication of pubic symphyseal plating. Here we present a case report of a 52-year-old female who presented with asymptomatic passage of screws in her urine following migration into the bladder, 2 years after symphyseal plating for pubic diastasis in an anteroposterior compression pelvic ring injury.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Chirurgie générale
/
Miction
/
Plaques orthopédiques
/
Vis orthopédiques
/
Accidents de la route
/
Migration d'un corps étranger
/
Diastasis de la symphyse pubienne
/
Diagnostic
/
Métaux
Type d'étude:
Etude diagnostique
Limites du sujet:
Femelle
/
Humains
langue:
Anglais
Texte intégral:
Chinese Journal of Traumatology
Année:
2013
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS