Some influence factors in determination of serum enzyme in hepatitis patients / 中华实验和临床病毒学杂志
Chinese Journal of Experimental and Clinical Virology
; (6): 385-387, 2008.
Article
Dans Zh
| WPRIM
| ID: wpr-332488
Responsable en Bibliothèque :
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To study some factors (temperature, time, anticoagulate, reagent, apparatus) which influence the detection of serum enzyme.</p><p><b>METHODS</b>Serums obtained from same patient are determined in different conditions. Compare the statistical difference among each group.</p><p><b>RESULTS</b>The anticoagulant-heparinize Li influence the determination of ADA and CH50. If serums were sent in room temperature for 24 hours, the results will be different. Using regents from different factories will receive different results.</p><p><b>CONCLUSION</b>Different conditions and reagents will influence results. To obtain correct data, we must institute and perform standard regulation.</p>
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Manipulation d'échantillons
/
Température
/
Sang
/
Protéines du système du complément
/
Prélèvement d'échantillon sanguin
/
Dosage de l'activité hémolytique du complément
/
Adenosine deaminase
/
Sérum
/
Équipement et fournitures
/
Hépatite
Limites du sujet:
Humans
/
Male
langue:
Zh
Texte intégral:
Chinese Journal of Experimental and Clinical Virology
Année:
2008
Type:
Article