Your browser doesn't support javascript.
loading
Clinical application of dual-source computed tomographic urography using dual-energy virtual non enhanced computed tomography / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 649-654, 2010.
Article Dans Chinois | WPRIM | ID: wpr-341482
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the clinical feasibility of dual-source computed tomographic urography using dual-energy virtual non-enhanced CT.</p><p><b>METHODS</b>Totally 240 patients received dual-source CT, which included true non-enhanced CT (TNCT) , nephrographic phase scanning with dual-energy mode (100kVp/230mAs and Sn140kVp/178mAs) , and excretory phase scanning. A contrast bolus injection of 100 ml (370 mgI/ml) contrast agent was applied (4.5ml/s) , followed by 100ml normal saline (4.5ml/s) . Virtual non-enhanced CT (VNCT) image sets were reformatted from 'Liver VNC ' software. The mean CT number, noise, signal to noise ratio (SNR) , image quality, and radiation dose were compared between TNCT and VNCT image sets.</p><p><b>RESULTS</b>There was no significant difference in mean CT numbers of all organs (P>0.05) . However, VNCT images had significantly lower noise and higher SNR than TNCT images (both P<0.05) . Image quality of VNCT was lower than that of TNCT without significant difference (P>0.05) . Radiation dose of nephrographic phase with dual-energy mode was significantly higher than that of TNCT and excretory phase scanning (P<0.05) .</p><p><b>CONCLUSION</b>Dual-energy VNCT requires less radiation dose and therefore has a potential to replace TNCT in the dual-source CT urography.</p>
Sujets)
Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Dose de rayonnement / Urographie / Tomodensitométrie / Radiographie digitale par projection en double énergie / Reproductibilité des résultats / Sensibilité et spécificité / Rapport signal-bruit / Méthodes Type d'étude: Etude diagnostique Limites du sujet: Adolescent / Adulte / Adulte très âgé / Aged80 / Femelle / Humains / Mâle langue: Chinois Texte intégral: Acta Academiae Medicinae Sinicae Année: 2010 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Dose de rayonnement / Urographie / Tomodensitométrie / Radiographie digitale par projection en double énergie / Reproductibilité des résultats / Sensibilité et spécificité / Rapport signal-bruit / Méthodes Type d'étude: Etude diagnostique Limites du sujet: Adolescent / Adulte / Adulte très âgé / Aged80 / Femelle / Humains / Mâle langue: Chinois Texte intégral: Acta Academiae Medicinae Sinicae Année: 2010 Type: Article