Your browser doesn't support javascript.
loading
Simultaneous determination of melamine and cyanuric acid residues in water and urine by solid phase extraction-hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry method / 中华预防医学杂志
Chinese Journal of Preventive Medicine ; (12): 641-647, 2013.
Article Dans Chinois | WPRIM | ID: wpr-355791
ABSTRACT
<p><b>OBJECTIVE</b>We aimed to establish a sensitive quantified method for the simultaneous determination of melamine and cyanuric acid residues in water and urine by hydrophilic interaction liquid chromatography coupled with electrospray tandem mass spectrometry (HILIC-ESI-MS/MS) with the pretreatment of hydrophilic functional silica gel and cation exchange resin mixed solid phase extraction column(MCT), and to investigate the melamine and cyanuric acid residues in 501 water and 216 urine from several province and city.</p><p><b>METHODS</b>About 100 ml water (or 10 ml urine) was adjusted to pH 3.0 with concentrated hydrochloric acid, and then mixed with the internal standard solution((15)N3-melamine and (15)N3-(13)C3 -cyanuric acid) and 100 ml acetonitrile (10 ml for urine). The solution was cleaned with MCT solid-phase extraction column, and eluted once by 3 ml methanol and twice by 2.5 ml methanol (containing 5% ammonia water). The effluent was collected and dried by N2 flow at 40 °C, and then diluted to 2 mmol/L ammonium acetate containing 90% volume fraction acetonitrile. The completely dissolved solution was then filtered with 0.22 µm organic membrane; and the filtrate was detected by high performance liquid chromatography-tandem mass spectrometry and quantified with internal standards. The repeatability and sensitivity of the assay were evaluated. Then we detected the melamine and cyanuric acid residues in 501 water and 216 urine samples collected from several province and city.</p><p><b>RESULTS</b>By the quantification of internal standard (15)N3-melamine and (15)N3-(13)C3-cyanuric acid, the melamine and cyanuric acid were linear in the range of 2.0-1000.0 µg/L with correlation coefficient of 0.9998 and 0.9997. The detection limits of the method were separately 0.4 ng/L (melamine) and 0.3 ng/L (cyanuric acid) for water, and 4.0 ng/L (melamine) and 3.0 ng/L (cyanuric acid) for urine. The average recovery rate was around 95.3%-100.1% with the relative standard deviation (RSD) was <4.02%. Out of the 501 water samples, melamine was detected out in 19.9% (100/501) and cyanuric acid was detected out in 5.2% (26/501). The content was around 0.03-5.00 g/L. Melamine or cyanuric acid was detected out in 24.5% of the urine samples (53/216), with the content around 0.01-1.00 g/L.</p><p><b>CONCLUSION</b>The established method of solid phase extraction-hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry can satisfy the requirement for detection of melamine and cyanuric acid residues in all sorts of water and urine. Meanwhile, the two substances widely existed in water and Chinese population.</p>
Sujets)
Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Spectrométrie de masse / Triazines / Urine / Surveillance de l&apos;environnement / Chromatographie en phase liquide / Examen des urines / Extraction en phase solide / Méthodes Limites du sujet: Humains langue: Chinois Texte intégral: Chinese Journal of Preventive Medicine Année: 2013 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Spectrométrie de masse / Triazines / Urine / Surveillance de l&apos;environnement / Chromatographie en phase liquide / Examen des urines / Extraction en phase solide / Méthodes Limites du sujet: Humains langue: Chinois Texte intégral: Chinese Journal of Preventive Medicine Année: 2013 Type: Article