Stanford Type A Acute Aortic Dissection Case Caused by Blunt Chest Trauma / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery ; : 159-162, 2013.
Article Dans Japonais | WPRIM | ID: wpr-374402
ABSTRACT
A 31-year-old man fell into syncope caused by compression by a machine in his factory. He was taken to the nearest hospital at once for treatment. His chest X-ray seemed normal and his general condition improved. He received no medical treatment and was allowed to return home. Two days later, he went to the hospital for further investigation, and contrast-enhanced chest computed tomography (CT) was performed. Chest CT showed aortic dissection from the ascending aorta to the aortic arch. Therefore, he was admitted for bed rest with antihypertensive therapy. He was discharged on the 35th day after the accident. However, the diameter of the ascending aorta was found to have become dilated, and so he underwent ascending aorta and hemiarch replacement at our hospital. His postoperative course was uneventful, and he was discharged on the 16th postoperative day. We report a rare case of an acute aortic dissection caused by blunt chest trauma.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Japonais Texte intégral: Japanese Journal of Cardiovascular Surgery Année: 2013 Type: Article