ABSTRACT
Objective To compare the dosimetric characteristics of helical tomotherapy(HT)and step-and-shoot intensity modulated radiotherapy(IMRT)for post-operative cervix cancer patients. Methods Ten patients with post-operative cervix cancer were enrolled in this study.HT and IMRT plans were developed for each patient.The dose distributions of the targets,organs at risk(OARs),CI and HI were analyzed and compared.The prescribed dose was 60 Gy/25 f for CTV1,50 Gy/25 f for CTV2.The iso-dose line of 50 Gy was used.Results The homogeneity indexes(HI)(0.94±0.03),conformity index(C1)(1.28±0.02)in HT group were better than in IMRT group(0.85±0.01 and 1.36±0.03),respectively(t=5.12,-6.34,P<0.001).The Dmean of PTV in HT group(51.77 Gy)was lower than that in IMRT group(54.53 Gy)(t=-8.01,P<0.05).The Dmax ,Dmean,V30,V40 and V50 of bladder、rectum and small bowel were lower in HT group than those in IM RT group.The Dmax,Dmean,V30 and V40 of right and left femoral head were lower in HT group than those in IMRT group.Conclusion Helical tomotherapy treatment plan has a better homogeneity,steeper dose gradient,and a better protection for organs at risk.
Mots clés
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Chinese Journal of Radiological Medicine and Protection Année: 2010 Type: Article
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Chinese Journal of Radiological Medicine and Protection Année: 2010 Type: Article