ABSTRACT
Objective To analysis the relation of the diameter of continuous curvilinear capsulorhexis and other factors with the capsular block syndrome.Methods We not only analyzed the etiology and clinical characteristic of six cases in intraoperative,early postoperative and lately postoperative,but also discussed the method of treatment.Results (1)When the diameter of CCC was smaller than the one of IOL's optic , the CBS easily happened; (2)When the hoops of the hydroview IOL had a smaller anterior angle and larger optic, the CBS easily happened; (3)When the viscoelestic material and cortex were stayed in capsular or anterior chamber, the CBS easily happened.Conclusion (1)Generaly speaking the size of the CCC should right on the edge of the IOL's optic part; (2)To hydroview IOL, we should choose the one which had a larger anterior angle and a smaller optic; (3)Viscoelastic material which should be cleaned and there was no the rest cortex stayed in the capsular.
Mots clés
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Recent Advances in Ophthalmology Année: 2001 Type: Article