The Usefulness of the PCL Power Calculation Computer Program: 'POWER!'
Journal of the Korean Ophthalmological Society
;
: 23-28, 2002.
Article
Dans Coréen
| WPRIM
| ID: wpr-45864
ABSTRACT
PURPOSE:
To assess the usefulness and reliability of the IOL power calculation computer program ('POWER!').METHODS:
Calculation times and projected postoperative refractive values of 100 patients with 'POWER!' program were compared with those of the program mounted on the Humphrey R A/B scan system (model 820) by SRK-II and SRK/T formula.RESULTS:
There was no significant difference between the projected postoperative refractive values of 'POWER!' program and Humphrey R A/B scan system (paired-t test, p>0.05). Calculation time of 'POWER!' was shorter than that of the program mounted on the Humphrey R A/B scan system incalculating more than 3 sets of IOL (paired-t test, P0.05).CONCLUSIONS:
'POWER!' is a useful and reliable program for IOL power calculation using SRK-II and SRK/T formula.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Limites du sujet:
Humains
langue:
Coréen
Texte intégral:
Journal of the Korean Ophthalmological Society
Année:
2002
Type:
Article