Analysis of locking plate in the treatment of proximal humerus fractures / 重庆医学
Chongqing Medicine ; (36): 667-669, 2015.
Article Dans Chinois | WPRIM | ID: wpr-460887
ABSTRACT
Objective To evaluate the clinical and radiological results of locking plate for treatment of proximal humerus frac‐tures and the efficacy of anatomical healing of tuberosities .Methods A total of 57 patients with proximal humerus fractures were treated with locking‐plate from July 2008 to March 2012 .A standardized radiological evaluation was conducted .Patients were divid‐ed into two groupsgroup A (anatomical healing of tuberosities) with 31 cases and group B (without anatomical healing of tuberosi‐ties) with 26 cases .Clinical assessment was performed using the Neer rating scale .Results Considering the entire sample ,the mean Neer score was 87 .96 ± 5 .06 points ,the excellent rate was 94 .74℅ .Comparing these parameters in the two groups ,group A was significant higher in the Neer scores and the range of movement than that of group B (P0 .05) .Conclusion the locing plate for treatment of complex proximal humerus fractures has a high subjective satisfaction rate .A good functional result depends on anatomical reestablishment of proximal humerus anatomy , particularly the healing of the greater tuberosity .

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chongqing Medicine Année: 2015 Type: Article