Your browser doesn't support javascript.
loading
Comparison of the incidences of apical root cracks after canal preparation with two nickel-titanium rotary systems:an in vitro study / 北京大学学报(医学版)
Journal of Peking University(Health Sciences) ; (6): 129-133, 2015.
Article Dans Chinois | WPRIM | ID: wpr-461085
ABSTRACT

Objective:

To compare the incidences of root cracks after canal instrumentation with HyFlex CM system and the ProTaper Universal system .

Methods:

Sixty mandibular incisors were mounted in resin blocks with simulated periodontal ligaments , and the apex was exposed .The control group of 20 teeth was not prepared , and the other 40 teeth were divided into 2 experimental groups ( n=20 ) .The 40 root canals of the experimental groups were instrumented using HyFlex CM and ProTaper Universal to the major apical foramen ( AF).The horizontal sections 1 mm, 2 mm, and 3 mm from the apex were observed under an optical stereomicroscope at 25 ×magnification .The presence of cracks was noted .

Results:

No cracks were found in the control teeth .Cracks were found in 1 of 20 ( 5%) teeth in HyFlex CM group , and 17 of 20 ( 85%) teeth in ProTaper Universal group .The difference between the two experimental groups was statistically significant (P<0.01).

Conclusion:

The HyFlex CM files caused fewer root cracks than the ProTaper Universal files during the root canal instrumentation .

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Journal of Peking University(Health Sciences) Année: 2015 Type: Article