Your browser doesn't support javascript.
loading
Role of the rotating insulin weekly abdominal injection card in safe injection of insulin in patients with type 2 diabetes mellitus / 中华健康管理学杂志
Chinese Journal of Health Management ; (6): 196-199, 2015.
Article Dans Chinois | WPRIM | ID: wpr-467301
ABSTRACT
Objective To investigate how to improve safety of insulin injection in type 2 diabetes patients by“insulin pen”through the rotating insulin weekly abdominal injection card. Method All the inpatients with type 2 diabetes in the Department of 3rd Internal Medicine from January to September, 2013 were enrolled in this study. Insulin Injection Card group was composed of 66 type 2 diabetes patients who were admitted from June to September, while control group was composed of 62 type 2 diabetes patients admitted from January to April. The difference between Insulin Injection Card group and control group was that the former group used the rotating insulin abdominal injection card weekly which was designed by ourselves, while the control group patients did not use the card. Every participant of both groups was evaluated at 2 weeks of treatment by percentage of patients having absence of Safety standard of insulin injection, and at the end of 3 months of treatment by percentage of patients attaining the therapeutic targets and incidence of adverse events. Result Compared with the control group, patients in Insulin Injection Card group had lower proportion of absence of Safety standard for insulin injection. The scores of rotation injection site in the two groups was 0.59±0.14 and 2.67±0.21(P<0.01). The rate of FPG target achievement of patients in Insulin Injection Card group (84.9%) was higher than that of the control group (61.3%)(P<0.01), the rate of HbA1c target achievement of patients in Insulin Injection Card group (78.8%) was higher than that of the control group (56.5%)(P<0.01). Patients in Insulin Injection Card group had lower incidence of local adverse events (1.5%) compared with the control group (12.9%)(P<0.05). Conclusion Use of the rotating insulin weekly abdominal injection card that was designed by the diabetes health management Quality Control Group in our department showed good effect in achieving therapeutic targets (including HBA1C) and decreasing safety standard deficiency of insulin injection and adverse events.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Health Management Année: 2015 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Health Management Année: 2015 Type: Article