Detection of serum HCV RNA in patients with chronic hepatitis C by transcription mediated amplification and real-time reverse transcription polymerase chain reaction / 中南大学学报(医学版)
Journal of Central South University(Medical Sciences)
;
(12): 664-672, 2014.
Article
Dans Chinois
| WPRIM
| ID: wpr-468218
ABSTRACT
Objective:
To observe the stability and sensitivity of transcription mediated ampliifcation (TMA) system, and to compare it with real-time reverse transcription polymerase chain reaction (RT-PCR) in amplifying serum HCV RNA in HCV infected patients.Methods:
TMA system was established by moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase and 2 speciifc primers ifrstly,and then its stability and repeatability were compared at different storage temperatures by the correlation change of HCV RNA amplification curve. The sensitivity difference between TMA and RT-PCR was evaluated by amplifying a group of 10-fold diluted HCV RNA samples which were transcribed in vitro. A total of 101 serums of chronic HCV infected patients were measured by TMA system and RT-PCR to observe the positive rate and their correlation. Linear correlation and linear regression were used to observe the correlation of the two methods.Results:
TMA system was successfully established. TMA system was not stable when stored at 20℃ (placed for 24 hours only), but it was stable for 6 days when stored at 4℃ or within 6 months when stored at-20 ℃. Compared with RT-PCR whose reagent was made by Hunan Sansure Biotechology Corporation, TMA system showed 20 positive samples and 11 negative samples in a total of 31 samples. So was the RT-PCR kit of the Sansure Biotechology Corporation, and the concordance rate of the two methods was 100%. Advanced quantitative study of the 20 positive samples found that the two methods had good correlation and consistency (r=0.91,P0.05). Advanced quantitative study of 29 positive samples found that the two methods had good correlation and consistency (r=0.96,P<0.01).Conclusion:
The stability and repeatability of TMA system are good within 6 months when stored at-20 ℃ storage temperature. Both TMA and RT-PCR HCV RNA can detect serum HCV RNA well, and the two methods have good correlation and consistency.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Type d'étude:
Etude diagnostique
langue:
Chinois
Texte intégral:
Journal of Central South University(Medical Sciences)
Année:
2014
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS