Your browser doesn't support javascript.
loading
Magnetization transfer contrast gradient echo T2WI sequence in the diagnosis of bone contusion of knee joint / 中国医学影像技术
Article de Zh | WPRIM | ID: wpr-471677
Bibliothèque responsable: WPRO
ABSTRACT
Objective To assess the diagnostic value of magnetization transfer contrast (MTC) gradient echo (GRE) T2WI sequence in bone injury of knee joint. Methods MRI data of 56 patients with knee injury were analyzed retrospectively. All patients underwent SE sequence (sagittal T1WI, T2WI) and sagittal MTC-GRE T2WI sequence. The size, signal intensity and margin of bone contusion with different MRI sequence were analyzed and compared. Results Among 56 patients, 43 and 45 cases were demonstrated on SE T1WI and T2WI, respectively; 50 cases were displayed on MTC-GRE T2WI sequence. The size, border of bone contusions and sensitivity displayed on MTC-GRE T2WI sequence were statistically higher than those on SE sequence (P<0.05). Conclusion MTC-GRE T2WI sequence has great diagnostic value in contusion of knee joint, which is superior to FSE sequence.
Mots clés
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Medical Imaging Technology Année: 2009 Type: Article
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Medical Imaging Technology Année: 2009 Type: Article