Cardiac arrest induced by tension pneumothorax during ventilating bronchoscopy: A case report / 대한마취과학회지
Korean Journal of Anesthesiology
; : 123-126, 2010.
Article
de En
| WPRIM
| ID: wpr-48087
Bibliothèque responsable:
WPRO
ABSTRACT
Tension pneumothorax during ventilating bronchoscopy for foreign body removal is a rare but life-threatening complication. The authors present a case of cardiac arrest caused by tension pneumothorax in a 9-month-old girl who underwent ventilating bronchoscopy for foreign body (peanut) removal. Tension pneumothorax was due to tracheobronchial lacerations caused by a bronchoscope. The patient was successfully resuscitated by cardiopulmonary resuscitation and chest tube insertion. The airway injury was effectively repaired by thoracotomy under extracorporeal membrane oxygenation.
Mots clés
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Pneumothorax
/
Bronchoscopie
/
Thoracotomie
/
Oxygénation extracorporelle sur oxygénateur à membrane
/
Drains thoraciques
/
Réanimation cardiopulmonaire
/
Bronchoscopes
/
Lacérations
/
Corps étrangers
/
Arrêt cardiaque
Limites du sujet:
Humans
/
Infant
langue:
En
Texte intégral:
Korean Journal of Anesthesiology
Année:
2010
Type: