Your browser doesn't support javascript.
loading
Determination of the Concentration of Midazolam in Plasma by RP-HPLC-UV Detection / 中国药房
China Pharmacy ; (12)1991.
Article Dans Chinois | WPRIM | ID: wpr-518790
ABSTRACT

OBJECTIVE:

To build up a method of determining the concentration of midazolam in plasma by RPHPLC-UV detection.

METHODS:

The separation was carried out by a reversed-phase Hypersil ODS column(250mm?4.0mm,5?m) with a mobile phase consisting of methanol-acetonitrile-0.02mol/L potassium phosphate buffer(pH 7.4) (65∶25∶10,V/V).Mida_zolam was extracted from alkalinizing plasma and soluted in the mobile phase then detected at 221nm.

RESULTS:

The calibration curve had the fine linearity in the concentration range 50~1 600ng/ml(r=0.9 999).The detection limit was 2ng/ml.The absolute recovery was 90.8%~95.4%,the relative recovery was 99.3%~101.3%.The within-day and between-day precision(CV%) was 1.94%~5.16%,3.00%~6.39% respectively.

CONCLUSION:

The method is simple,stable and highly sensitive and could meet with the research of clinical pharmacokinetics.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Type d'étude: Etude diagnostique langue: Chinois Texte intégral: China Pharmacy Année: 1991 Type: Article