Determination of ampicillin and probenecid concentration in human plasma by high performance liquid chromatography / 第三军医大学学报
Journal of Third Military Medical University
; (24)1988.
Article
de Zh
| WPRIM
| ID: wpr-558500
Bibliothèque responsable:
WPRO
ABSTRACT
Objective To develop a high performance liquid chromatography(HPLC) method to determine the concentration of ampicillin and probenecid in human plasma.Methods A Symmetry ShieldTM RP18 column(5 ?m,150 mm?3.9 mm)was used.The mobile phases were 0.068 mol/L KH_2PO_4(pH 3.0)∶acetonitre(92∶8,V/V)for ampicillin,H_2O∶acetonitrile∶1 mol/L KH_2PO_4∶1 mol/L acetic acid(59.5∶39.8∶0.62∶0.062,V/V,0.15% triethylamine added to reach pH 2.76) for probenecid.The detective wavelength were at 254 nm for probenecid and 210 nm for ampicillin.Results The calibration curves obtained were linear in the range of 0.625-20 ?g/ml (r=0.999 9) of probenecid and 1.25-40 ?g/ml of ampicillin.Conclusion This analysis method is simple,sensitive and rapid,suitable for studying pharmacokinetics of ampicillin and probenecid.
Texte intégral:
1
Indice:
WPRIM
langue:
Zh
Texte intégral:
Journal of Third Military Medical University
Année:
1988
Type:
Article