Your browser doesn't support javascript.
loading
Bacterial Endotoxin Test of Pulse-Engendering Injection / 中成药
Chinese Traditional Patent Medicine ; (12)1992.
Article Dans Chinois | WPRIM | ID: wpr-569832
ABSTRACT

Objective:

To perform the bacterial endotoxin test of Pulse-Engendering Injection.

Methods:

The interference actions of the different dilutabilities of injection at the greatest effective diluent range were observed with some sensitivity of TAL.

Results:

When 0.5EU/ml sensitivity of TAL was used and the dilutability of sample was 1∶8, the injection showed obvious enhancement action, but when 0.25EU/ml senitiity of TAL was used and the dilutability was 1∶16, the enhancement action of injection could be eliminated.

Conclusion:

The bacterial endoxin test can be carried out with 0.25EU/ml sensitivity of TAL when the dilutability of sample is 1∶16, the limit dose of bacterial endotoxin is controlled thereby.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Traditional Patent Medicine Année: 1992 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Traditional Patent Medicine Année: 1992 Type: Article