Your browser doesn't support javascript.
loading
Porcine anterior segment perfusion culture and trabecular meshwork organ culture / 基础医学与临床
Basic & Clinical Medicine ; (12)2006.
Article Dans Chinois | WPRIM | ID: wpr-589257
ABSTRACT
Objective To verify the application of anterior segment perfusion culture and trabecular meshwork (TM) organ culture for glaucoma study. Methods TM tissue was cultured by perfused anterior segment and TM organ culture, light microscopy was used to observe the TM cells and intercellular spaces.Results IOP of the porcine anterior segments perfused under constant flow at 0.1 mL/h could bekept in normal range(10~12 mmHg). The IOP was elevated with the increasing of perfusion rate, while the morphology and structure of the tissue were well preserved. TM cultured by TM organ culture could also reserve the tissues well, but the intercelluar spaces collapsed. Conclusion Anterior segment perfusion model could be a short-term high-pressure model and may simulate the normal physical state. Adequate perfusion was necessary for normal TM.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Basic & Clinical Medicine Année: 2006 Type: Article