ABSTRACT
Objective To establish an UPLC method for the determination of sinomenine in Sinomenine External Applied Powder. Methods The UPLC method was carried out on a C18 column by using acetonitrile-water-ethylene diamine (50:50:0.25) as mobile phase. The flow rate was 0.2 mL/min; the sample quantity was 2 μL; the detection wavelength was 283 nm. Results The peak time was within 1 min or so. The calibration curve of sinomenine was in the linear range of 34.2–2188.0 ng. Conclusion The method is simple, rapid, stable and reliable, which can be used for the determination of sinomenine in Sinomenine External Applied Powder.