Application and comparison of EBUS-TBNA and conventional TBNA technology in diagnosis of mediastinal and lung hilar lesions / 中国内镜杂志
China Journal of Endoscopy
;
(12): 1-7, 2017.
Article
Dans Chinois
| WPRIM
| ID: wpr-612173
ABSTRACT
Objective To evaluate the diagnostic value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and conventional-transbronchial needle aspiration (C-TBNA) in mediastinal and lung hilar lesions. Method 301 cases of lung hilar and mediastinal lesions were selected from 2010 to 2016. Among them, 183 cases underwent TBNA, and the other 118 cases received EBUS-TBNA technology. During the research, the associations of diagnostic positive rate and complications were analyzed in order to explore the advantage and the value of EBUS-TBNA. Results The positive rates of EBUS-TBNA in central groups (2R, 4L, 4R, 7) were higher than in the peripheral groups (10R, 10L, 11R, 11L) (P 0.05), an approving effect of puncture can be acquired; The accuracy and sensitivity of EBUS-TBNA in the diagnosis of lung hilar and mediastinal lesions were much better than conventional TBNA (P 0.05), there were no severe complications during the operations in all cases. Conclusion EBUS-TBNA is useful in diagnosis of mediastinal and hilar lesions of unknown reason, and significant in diagnosis of bronchial and extrabronchial diseases. It is an efficiency and safe operation while further application studies are needed.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Type d'étude:
Etude diagnostique
langue:
Chinois
Texte intégral:
China Journal of Endoscopy
Année:
2017
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS