Your browser doesn't support javascript.
loading
Effects of different fabricating methods on the microleakage for preformed fiber posts / 实用口腔医学杂志
Journal of Practical Stomatology ; (6): 117-119, 2017.
Article Dans Chinois | WPRIM | ID: wpr-612986
ABSTRACT
To compare the microleakage of fiber post and resin-core system fabricated by different methods.The roots of 36 recently extracted single-rooted mandibular premolars were undergone endodontic treatment.Fiber posts and Paracore flowable resin composite were used for fabricating post-core restorations.Microleakage was examined by dye penetration method.The microleakage value was significantly higher in Direct-Mold-Cement-Method group(4.94 ± 1.71) mm compared to Direct-Mold-Secondary-Cement-Method group(0.91 ±0.33) mm and Indirect-Mold-Secondary-Cement-Method group (0.87 ± 0.27) mm (P < 0.05).

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Journal of Practical Stomatology Année: 2017 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Journal of Practical Stomatology Année: 2017 Type: Article