Your browser doesn't support javascript.
loading
Comparison of the hybrid locking plate, standard dynamic compression plate, and standard dynamic compression plate augmented with bone cement for fixation of osteoporotic humeral shaft fractures: A cadaveric biomechanical study
Acta Medica Philippina ; : 24-31, 2012.
Article Dans En | WPRIM | ID: wpr-633794
Responsable en Bibliothèque : WPRO
ABSTRACT
BACKGROUND: Studies comparing the relative strength of polymethylmethacrylate (PMMA) augmented fixation, standard plating and locked compression plate (LCP) system are few. The use of either the bone cement-augmented dynamic compression plate or the Hybrid LCP constructs may provide an additional tool for the treatment of fractures in patients with osteoporosis. METHODS: Eighteen (18) osteoporotic cadaveric humeral bones were assigned randomly to each of three groups (Dynamic Compression Plate [DCP], DCP augmented with bone cement, and the Hybrid LCP system) and tested in anterior-posterior bending and torsion/external rotation. The load to failure values were obtained and the results for each specimen compared. RESULTS: Significant differences were observed between the standard DCP and Hybrid LCP group (p-value=0.012), and in the cement-augmented and Hybrid LCP group (p-value=0.099) in torsion/external rotation loading. No significant difference was observed between the standard DCP and bone-cement augmented group (p-value=0.248). No significant difference was observed among the three groups in terms of stiffness (p-value=0.3868) in the four-point anterior-posterior bending modality. Screw pull-out of the implant was observed only in the regular DCP group in torsion/external rotation loading stress. CONCLUSION: Significant differences were seen between the three constructs in torsion/external rotation but not in anterior-posterior four-point bending. Bone failure, but not screw pull-out, was seen in the Hybrid LCP and bone cement-augmented DCP groups in torsion. This study showed that the LCP system and the bone cement-augmented constructs may provide greater screw purchase to the osteoporotic humerus.
Sujets)

Texte intégral: 1 Indice: WPRIM Sujet Principal: Ostéoporose / Rotation / Ciments osseux / Plaques orthopédiques / Vis orthopédiques / Poly(méthacrylate de méthyle) / Fractures osseuses / Ostéosynthèse interne / Humérus Limites du sujet: Humans langue: En Texte intégral: Acta Medica Philippina Année: 2012 Type: Article
Texte intégral: 1 Indice: WPRIM Sujet Principal: Ostéoporose / Rotation / Ciments osseux / Plaques orthopédiques / Vis orthopédiques / Poly(méthacrylate de méthyle) / Fractures osseuses / Ostéosynthèse interne / Humérus Limites du sujet: Humans langue: En Texte intégral: Acta Medica Philippina Année: 2012 Type: Article