Clinical study on all capsule polishing mode for decreasing the occurrence of posterior capsular opacification / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science
; (12): 1143-1144, 2014.
Article
de Zh
| WPRIM
| ID: wpr-641848
Bibliothèque responsable:
WPRO
ABSTRACT
AIM:To evaluate the effect of all capsule polishing with polishing mode for decreasing the occurrence of posterior capsular opacification( PCO) . METHODS: Totally 194 eyes ( 162 patients ) were performed phacoemulsification, posterior chamber intraocular lens were implanted. One hundred eyes were performed with all capsule polishing with polishing mode;94 eyes were performed with the polishing apparatus. RESULTS:The patients were followed up for 12mo. Six eyes ( 6. 0%) of PCO were found in the 100 eyes with polishing mode group; 15 eyes ( 16. 0%) of PCO were found in the 94 eyes with the polishing apparatus group. The difference was significant (P CONCLUSION: It can decrease the occurrence of PCO by performing all capsule polishing with polishing mode.
Texte intégral:
1
Indice:
WPRIM
langue:
Zh
Texte intégral:
International Eye Science
Année:
2014
Type:
Article