Placement of a pulmonary artery catheter is associated with various complications, including catheter knotting. Fluoroscopy can be used to visualize and confirm catheter knotting. Transesophageal echocardiography is readily available to detect knot formation in the operating room or intensive care unit. We present a case in which pulmonary artery catheter knotting was detected by transesophageal echocardiography. This method may be useful in the operating room or in the intensive care unit to identify the presence and location of catheter knotting.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Blocs opératoires / Artère pulmonaire / Radioscopie / Échocardiographie transoesophagienne / Cathéters / Unités de soins intensifs Type d'étude: Etude diagnostique langue: Anglais Texte intégral: The Korean Journal of Critical Care Medicine Année: 2011 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Blocs opératoires / Artère pulmonaire / Radioscopie / Échocardiographie transoesophagienne / Cathéters / Unités de soins intensifs Type d'étude: Etude diagnostique langue: Anglais Texte intégral: The Korean Journal of Critical Care Medicine Année: 2011 Type: Article