Reconstruction of Bony Orbit Using Endoscope and Polyethylene with Embedded Titanium for a Patient with Postoperative Enophthalmos / 대한이비인후과학회지
Korean Journal of Otolaryngology - Head and Neck Surgery
;
: 928-931, 2009.
Article
Dans Coréen
| WPRIM
| ID: wpr-648371
ABSTRACT
Enophthalmos means displacement of the globe into the bony orbit backward, and usually downward. In post-traumatic enophthalmos, the mechanisms that determine the globe position can be the enlargement of the orbital cavity, the herniation of orbital fat into the maxillary sinus, fat atrophy, loss of ligament support, and scar contracture. It can be reconstructed through several approaches such as transconjunctival, canthotomy, lower eye lid, coronal approach, and by using bone, cartilage, and alloplastic materials. The authors report a case of postoperative enophthalmos reconstructed through subciliary and transnasal endoscopic approaches using porous polyethylene with embedded titanium.