ABSTRACT
BACKGROUND AND OBJECTIVES:
Automated DPOAE (Distortion product otoacoustic emission) was tested on workers exposed to a noisy environmnent to determine its feasibility as a screening test for noise-induced hearing loss. SUBJECTS ANDMETHOD:
Sensitivity and specificity were analyzed for in both automated DPOAE and Pure tone audiometry conducted on 300 subjects working in a noisy environment. Of these subjects, a subgroup of 40 workers who were available for a follow-up study underwent the same experiment again a year later, and the results were compared with the first one.RESULTS:
In terms of the frequency of automated DPOAE, it was noted that it showed 91% sensitivity with a 9% false negative rate. The pass rate according to the period of service indicated statistical significance, although the results of a 1 year follow-up experiment did not indicate statistical significance.CONCLUSION:
The automated DPOAE seems feasible to use as a screening test when frequency and adjusted reference criteria are considered.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Audiométrie
/
Dépistage de masse
/
Études de suivi
/
Sensibilité et spécificité
/
Surdité due au bruit
Type d'étude:
Etude diagnostique
/
Étude observationnelle
/
Étude pronostique
/
Étude de dépistage
langue:
Coréen
Texte intégral:
Korean Journal of Otolaryngology - Head and Neck Surgery
Année:
2006
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS
LIS