Your browser doesn't support javascript.
loading
Position-induced Cyclotorsion under Monocular Fixation
Journal of the Korean Ophthalmological Society ; : 111-116, 2005.
Article Dans Coréen | WPRIM | ID: wpr-69688
ABSTRACT

PURPOSE:

To determine whether cyclotorsion occurs when a patient moves from the seating to supine position fixating with one eye.

METHODS:

The axis of astigmatism was measured with the handheld automated refractometer (Retinomax K-plus, Nikon, Japan) in 33 eyes having more than -1.0D cylinder in seated and supine positions under monocular fixation.

RESULTS:

There was a cyclotorsional deviation in 30 eyes (90.90%). Excyclotorsion was shown in 22 eyes (66.67%) and incyclotorsion in 8 (24.24%). Seventeen eyes (51.50%) had a torsional deviation less than 4 degrees, 5 eyes (15.15%) from 5 to 6 degrees, 7 eyes (21.21%) from 7 to 14 degrees and one eye greater than 15 degrees.

CONCLUSIONS:

Positionally induced cyclotorsion occurs under fixation with one eye simulating refractive surgery. Surgeons should therefore make an effort to align the wavefront measurement to the ablation onto the cornea.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Astigmatisme / Axis / Décubitus dorsal / Cornée / Procédures de chirurgie réfractive Limites du sujet: Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2005 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Astigmatisme / Axis / Décubitus dorsal / Cornée / Procédures de chirurgie réfractive Limites du sujet: Humains langue: Coréen Texte intégral: Journal of the Korean Ophthalmological Society Année: 2005 Type: Article