Your browser doesn't support javascript.
loading
Quality Evaluation of Shuwei Mixture Based on Multi-index Constituents / 医药导报
Herald of Medicine ; (12): 1396-1400, 2018.
Article Dans Chinois | WPRIM | ID: wpr-701037
ABSTRACT
Objective The quality evaluation of the Shuwei mixture was determined by the content of the six components of sinapine cyanide sulfonate, magnolol, honokiol, hesperidin, naringin and neohesperidin. Methods RP-HPLC method was used.The separation was performed on a Agilent ZORBAX Eclispse SB-C18column (4.6 mm×250 mm,5 mm),the mobile phase consisted of acetonitrile(A)-0.1% phosphoric acid with gradient elution at the flow rate of 1.0 mL·min-1.The detection wavelength was 326 nm ( sinapine cyanide sulfonate ), 294 nm ( magnolol, honokiol ) and 283 nm ( naringin, neohesperidin).The column temperature was kept at 30 ℃. Results The sinapine cyanide sulfonate, magnolol, honokiol, hesperidin,naringin and neohesperidin all had good linear relationship in the ranges of 0.049 6-1.24,0.048 2-1.205,0.060 5-1.512 5,0.187 2-4.68,0.131 6-3.29,0.197-4.925 μg.The average recoveries were 100.66%, 99.86%, 101.37%, 102.41%, 99.01%, 102.05%, respectively, RSD were 0.82%, 1.89%, 2.56 %, 0.74%, 1.54%, 0.99%, respectively. Conclusion The method is simple,accurate,reproducible and nice to the separation,and can be used for the quality evaluation of Shuwei mixture.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Herald of Medicine Année: 2018 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Herald of Medicine Année: 2018 Type: Article