Clinical evaluation of the fine impression technique for removable partial dentures / 口腔疾病防治
Journal of Prevention and Treatment for Stomatological Diseases
;
(12): 779-784, 2018.
Article
Dans Chinois
| WPRIM
| ID: wpr-758032
ABSTRACT
Objective@# To provide a clinical reference by evaluating the restorative results of an accurate impression technique for distal-extension removable partial dentures.@*Methods@#Forty-two patients with free-end dentition defects who visited the Prosthodontic Department of Nanjing Stomatological Hospital, Medical School of Nanjing University, between April 2017 and January 2018 were selected. The final impression was made by an accurate impression technique to fabricate fifty-two removable partial dentures with casting frameworks. The restorative result was judged by clinical examination and patient feedback immediately after wearing dentures and at 1 week, 3 months and 6 months.@*Results@#All fifty-two dentures for forty-two patients were seated successfully, with good retention and stability. Complications occurred throughout the 6-month follow-up, including 4 cases of mucous pain, 4 cases of retention force attenuation and 1 case of abutment fracture. There were no periodontics problems. The dentures garnered high patient satisfaction.@*Conclusion@#The accurate impression technique for distal-extension removable partial dentures showed good clinical results in this follow-up investigation.