Your browser doesn't support javascript.
loading
The in vivo thrombosis evaluation for the biodegradable polymer stent / 生物医学工程学杂志
Journal of Biomedical Engineering ; (6): 232-237, 2019.
Article Dans Chinois | WPRIM | ID: wpr-774216
ABSTRACT
New biodegradable intravascular stent can reduce risk of foreign bodies retained, thus, it is widely concerned and some of the products have been introduced into the clinic. However, the characteristic of biodegradable may lead to more safety concerns associated with thrombosis. To ensure the safety, the thrombus formation experiment needs to be carefully designed and evaluated based on GB/T 16886.4 standard, but current standard do not provide explicit testing and evaluating methods. Establishing animal model with experimental pigs, the study compares biodegradable coronary stents and metal stents by simulating clinical implantation on the thrombus formation in the implanting process, and after the short-term and long-term implantation. The evaluation methods include gross observation, digital subtraction angiography intraoperative analysis, optical coherence tomography analysis, scanning electron microscopy and so on. The results show that combining these methods could comprehensively evaluate the whole process of the thrombus formation from the beginning of implantation to the end of preclinical animal experiments, so that, it may better predict the clinical thrombosis risk, and the selection of the control was very important. The study tries to use the comparison examples of thrombosis on the new medical instrument to provide the clue for thrombosis evaluation on similar instruments and show the methodology on the preclinical evaluation.
Sujets)

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Polymères / Suidae / Thrombose / Résultat thérapeutique / Implant résorbable / Tomographie par cohérence optique / Endoprothèses à élution de substances Type d'étude: Étude pronostique Limites du sujet: Animaux langue: Chinois Texte intégral: Journal of Biomedical Engineering Année: 2019 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Polymères / Suidae / Thrombose / Résultat thérapeutique / Implant résorbable / Tomographie par cohérence optique / Endoprothèses à élution de substances Type d'étude: Étude pronostique Limites du sujet: Animaux langue: Chinois Texte intégral: Journal of Biomedical Engineering Année: 2019 Type: Article