Your browser doesn't support javascript.
loading
Positions of the implanted stimulating electrodes for artificial facial nerve for inducing contraction of the orbicularis oris muscle in rabbit with peripheral facial paralysis / 中华耳鼻咽喉头颈外科杂志
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 841-845, 2017.
Article Dans Chinois | WPRIM | ID: wpr-809554
ABSTRACT
Objective@#To explore the optimal positions of the implanted stimulating eletrodes for artificial facial nerve (AFN) for inducing contraction of the orbicularis oris muscle (OOM) in rabbit with peripheral facial paralysis.@*Methods@#According to the four microelectrodes of the AFN stimulating side, four modes of the implanted positions were divided. In line with different modes, the electrodes were implanted into the affected OOM of the rabbits with unilateral peripheral facial paralysis. AFN output electric stimulation to induce contraction of the affected OOM with uniform stimulating frequency and pulse length in vitro. Then compared the stimulus threshold amplitude and the peak amplitude separately among different modes by SAS 9.3 version statistical software.@*Results@#The differences of the stimulus threshold amplitude and the peak amplitude had no statistically significant separately between the first mode and the second mode (P>0.05), but there were statistically significant differences between the third mode and the fourth mode (P<0.05). Both kinds of the amplitudes were approximated between the first mode and the second mode respectively, and higher than those in the third mode or the fourth mode. Furthermore, both kinds of the amplitudes in the fourth mode were higher than those in the third mode.@*Conclusions@#The microelectrodes of the AFN stimulating lateral are implanted into the upper lip with a public microelectrode and an output microelectrode, into the lower lip with an output microelectrode, and into the way, which is located to the angle 40° to 45° about the line joining between the midpoint of the ipsilateral auricle root and the corner of the mouth with an output microelectrode. This is the third positional mode which requires lowest effective stimulus current intensity. Thus the mode is suitable as the optimal placement programme.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Année: 2017 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Otorhinolaryngology Head and Neck Surgery Année: 2017 Type: Article