Your browser doesn't support javascript.
loading
Study on Detection Methods for Related Substances in Fidaxomicin Raw Material / 中国药房
China Pharmacy ; (12): 581-585, 2020.
Article de Zh | WPRIM | ID: wpr-817314
Bibliothèque responsable: WPRO
ABSTRACT
OBJECTIVE:To establish th e method for the determination of related substances in fidaxomicin raw material. METHODS:The detection ability of NP-HPLC-UV ,RP-HPLC-ELSD and RP-HPLC-UV systems for the related substances in fidamycin raw material was investigated and the best chromatographic system was selected . The HPLC detection method for the related substances was established. The detection was performed on Agilent Eclipse XDB C 18 column with mobile phase A consisted of 0.2% triethylamine buffer solution (pH 3.8)-acetonitrile(55∶45,V/V),mobile phase B consisted of 0.2% triethylamine buffer solution(pH 3.8)-acetonitrile(20∶80,V/V)at the flow rate of 1.0 mL/min(gradient elution );the detection wavelength was set at 230 nm,and column temperature was 35 ℃;the sample size was 10 µL. Calculation of the content of related substances was principal component self-control method without correction factor. RESULTS :The impurities C and F could not be separated effectively in NP-HPLC-UV system. In RP-HPLC-ELSD system ,only impurities C ,D,E and F could be detected. In RP-HPLC-UV system ,11 impurities could be detected. In the study of methodology ,the linear ranges were 0.5-20.0 μg/mL for fidaxomicin(R2=0.999 9);the LOD was 0.05 ng,LOQ was 0.15 ng;RSDs of reproducibility and intermediate precision tests were less than 2.0%(n=6);average recovery was 98.4%(RSD=3.6%,n=9). The sum of impurities in 3 batches of raw materials were 0.53%,0.51%,0.51%,respectively. CONCLUSIONS :The effect of detecting impurities by RP-HPLC-UV are the best. Established method is specific and sensitive ,and can be used for the determination of related substance in fidaxomicin raw material.
Mots clés
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: China Pharmacy Année: 2020 Type: Article
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: China Pharmacy Année: 2020 Type: Article