Your browser doesn't support javascript.
loading
Modified knee spreader combined with minimally invasive percutaneous plate internal fixation for complex tibial plateau fractures / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 4305-4309, 2020.
Article Dans Chinois | WPRIM | ID: wpr-847371
ABSTRACT

BACKGROUND:

Studies have shown that the adjuvant use of long bone distraction device for unstable tibial plateau fractures achieved satisfactory results, but the safety of its use of long bone distraction device is not high, and the device could easily lead to soft tissue damage.

OBJECTIVE:

To compare the clinical efficacy of modified knee joint spreader combined with minimally invasive percutaneous plate internal fixation and traditional incision reduction plate internal fixation for the treatment of complex tibial plateau fractures.

METHODS:

A total of 71 patients with complicated tibial plateau fractures admitted to Xiangdong Hospital Affiliated to Hunan Normal University from January 2016 to January 2018 were included, including 48 males and 23 females. The 34 patients in the experimental group received modified knee spreaders combined with minimally invasive percutaneous plate internal fixation treatment. The 37 patients in the control group received traditional open reduction and plate internal fixation. The incision length, operation time, intraoperative blood loss, hospital stay, the time of fracture healing and the incidence of postoperative complications were compared between the two groups. Knee HSS scores were assessed at 1 month and at the last follow-up. The trial was approved by the Ethics Committee of Xiangdong Hospital Affiliated to Hunan Normal University. RESULTS AND

CONCLUSION:

(1) The operation time, intraoperative blood loss, incision length, and hospital stay were shorter in the experimental group than in the control group (P 0.05). (2) One case of joint stiffness and one case of traumatic arthritis were found in the experimental group. One case of postoperative infection, five cases of joint stiffness, one case of traumatic arthritis and one case of loosening of the internal fixation were found in the control group. The incidence of complications in the experimental group was less than that in the control group (P 0.05). (4) The results showed that compared with the traditional open reduction and internal fixation, the modified knee spreader combined with minimally invasive percutaneous plate internal fixation for complex tibial plateau fractures can improve the operation efficiency, reduce surgical trauma, reduce the incidence of postoperative complications, and shorten hospital stay for patients.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Tissue Engineering Research Année: 2020 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Tissue Engineering Research Année: 2020 Type: Article