Determination of polycyclic aromatic hydrocarbons in traditional Chinese medicines by isotope dilution gas chromatography-tandem mass spectrometry / 中国药学杂志
Chinese Pharmaceutical Journal ; (24): 115-119, 2015.
Article Dans Chinois | WPRIM | ID: wpr-859346
ABSTRACT

OBJECTIVE:

To develop a GC-MS/MS method for the determination of the residues of 16 polycyclic aromatic hydrocarbons (PAHs) in Chinese herbal medicines.

METHODS:

Using isotope as internal standard, the sample was extracted by ethyl acetate and purified by solid phase extraction on C18 cartridges. GC-MS/MS method was used for the assay, with analyte protectants added to counteract the matrix effect. The chromatographic column was DB-5ms(0.25 mm × 30 m, 0.25 μm) with temperature programming and MRM detection.

RESULTS:

The calibration curves for the 16 kinds of typical PAHs were linear in the range of 1 - 100 ng · mL-1. The average recovery rate was 88.53% - 119.03% in the range of 1 -25 μg · kg-1 with RSDs of 1.25% - 14.70% (n = 3). The LOQs were 0.2 - 1 μg · kg-1.

CONCLUSION:

This method is specific, sensitive, accurate and can be used for residue detection of 16 typical kinds of PAHs in Chinese herbal medicines.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Pharmaceutical Journal Année: 2015 Type: Article