Your browser doesn't support javascript.
loading
Testing tetrahydrofuran in the air of workplace by solvent desorption-gas chromatography / 中国职业医学
China Occupational Medicine ; (6): 197-200, 2016.
Article Dans Chinois | WPRIM | ID: wpr-876932
ABSTRACT

OBJECTIVE:

To establish a method for testing tetrahydrofuran( THF) in workplace air by solvent desorption gas chromatography.

METHODS:

The air samples were collected by activated carbon tube,desorbed with carbon disulfide solution,then separated by capillary column and detected by flame ionization detector.

RESULTS:

The linearity range of THF concentration was 1. 78-8 892. 00 mg / L,and the correlation coefficient was 0. 999 9. The minimum detection limit of THF was 0. 09 mg / m3. The minimum quantitative concentration was 0. 27 mg / m3( 3. 00 L air collection). The average desorption efficiency of THF was 94. 29%-96. 46% when placed overnight at the room temperature. The within-run and the between-run relative standard deviation were 0. 30%-0. 91% and 0. 66%-1. 23% respectively. THF sample could be stored at room temperature for at least 8 days.

CONCLUSION:

The method could be widely applied in sampling and detection of THF in workplace air.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: China Occupational Medicine Année: 2016 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS