Comparison of the Consistency and Difference of Three Detection Methods in Blood Concentration Monitoring of Mycophenolic Acid / 中国药房
China Pharmacy ; (12): 2885-2889, 2021.
Article Dans Chinois | WPRIM | ID: wpr-906656
ABSTRACT
OBJECTIVE:To investigate the consistency and difference of f luorescence immunochromatographic and liquid chromatography-tandem mass spectrometryLC-MS/MS)and enzyme multiplied immunoassay technique (EMIT)in the blood concentration monitoring of mycophenolic acid. METHODSFluorescence immunochromatographyLC-MS/MS and EMIT were used to detect the blood concentration of mycophenolic acid in 61 blood samples of children treated with mycophenolate mofetil ester orally at different time points. Kolmogorov-Smirnov method ,Wilcoxon pairing test ,Passing-Bablok regression ,Cusum method,Spearman correlation analysis ,Bland-Altman scatter diagram were adopted for statistical analysis. RESULTS :Blood concentrations of mycophenolic acid ,which were determined by fluorescence immunochromatographyLC-MS/MS and EMIT , showed non-normal distribution. Passing-Bablok regression analysis showed that regression equation of fluorescence immunochromatography and LC-MS/MS ,fluorescence immunochromatographic method and EMIT were CFI=0.928 3CLC-MS/MS+0.961 7 and CFI=0.880 7CEMIT-0.488 2(FI means fluorescence immunochromatographic ). Spearman correlation analysis showed that the correlation coefficients between fluorescence immunochromatography and LC-MS/MS ,fluorescence immunochromatography and EMIT were 0.968 and 0.929, respectively (P<0.000 1). Bland Altman scatter plot analysis showed that 3.28% of the 358341451@qq.com difference between fluorescence immunochromatography and LC-MS/MS was outside the consistency limit (±1.96SD), and 1.64% of the difference between fluorescence immuno- chromatography and EMIT was outside the consistency limit (± 1.96SD). Wilcoxon pairing test showed that the results of fluorescence immunochromatography were higher than those of LC-MS/MS (Z=3.76,P=0.000 2)and lower than those of EMIT (Z=-5.96,P<0.000 1). CONCLUSIONS :Fluorescence immunochromatography shows good consistency and correlation with LC-MS/MS and EMIT ;the blood concentrations of mycophenolic acid detected by fluorescence immunochromatography were higher than those by LC-MS/MS and lower than those by EMIT . It can be used for bedside rapid detection. When using the test results of different methods for clinical medication ,the differences of test methods need to be considered.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Type d'étude: Etude diagnostique langue: Chinois Texte intégral: China Pharmacy Année: 2021 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Type d'étude: Etude diagnostique langue: Chinois Texte intégral: China Pharmacy Année: 2021 Type: Article