ABSTRACT
PURPOSE: Tc-99m Tetrofosmin is a new alternative to Tc- 99m MIBI for nuclear breast imaging. A receiver operating characteristic (ROC) curve analysis was performed to evaluate the feasibility of Tc-99m Tetrofosmin quantitative scintimammography (SMM) (qSMM) and to compare with previously reported Tc-99m MIBI qSMM data [J Kor Surg 1999;57(5):638-644)]. METHODS: Prone anterior, lateral planar and supine SPECT images were taken from 135 cases in 131 female patients (mean ages=44 yr) with breast mass (size> or =0.2 cm) after 30mCi intravenous injection of Tc-99m Tetrofosmin. 70 malignant and 65 benign lesions were histologically proven. Three regions of interest (ROIs) were drawn over designated areas: the Lesion (L), the Normal breast opposite the lesion (NL) and the right Chest wall (CW). L/NL and L/CW ratios on both the SPECT and the planar images were analyzed. RESULTS: ROC curve analysis revealed that the planar L/NL ratio and the SPECT L/NL and L/CW ratios had higher diagnostic accuracy for detecting breast cancer than he planar L/CW ratio did (P<0.05). The qSMM (mean), which is an arithmetic mean of the planar L/NL ratio, the SPECT L/NL ratio and the SPECT L/CW ratio, the sensitivity, the specificity, accuracy and area under curve (AUC) were 82.9%, 81.5%, 82.2% and 0.879 respectively. Presence of axillary lymph node metastasis showed a slightly higher qSMM (mean) value (2.79 {n=23} vs 2.75 {n=27} P=0.06). These are comparable with previously reported Tc-99m MIBI qSMM data of 84.4%, 76.6%, 81.0% and 0.847 respectively, and the presence of axillary lymph node metastasis showed a higher qSMM(mean) value (4.09 {n=17} vs 3.09 {n=28}, P=0.06) [J Kor Surg 1999; 57(5):638-644)]. CONCLUSION: Tc-99m Tetrofosmin qSMM (mean) is a useful and objective method for differentiating malignant from benign breast lesion and has the comparable diagnostic accuracies of Tc-99m MIBI qSMM.
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Région mammaire
/
Tumeurs du sein
/
Tomographie par émission monophotonique
/
Courbe ROC
/
Sensibilité et spécificité
/
Aire sous la courbe
/
Paroi thoracique
/
Injections veineuses
/
Noeuds lymphatiques
/
Métastase tumorale
Type d'étude:
Diagnostic_studies
/
Prognostic_studies
Limites du sujet:
Female
/
Humans
langue:
Ko
Texte intégral:
Journal of Korean Breast Cancer Society
Année:
2004
Type:
Article