Objective:
To provide the calculation method for evaluating and designing the volume of nuclear medicine intermittent decay pool, so as to provide technical reference for medical institutions, environmental impact assessment institutions and management departments, etc.Methods:
By constructing a mathematical model and deriving the calculation formula, the relationship between the volume of intermittent decay pool and the radioactivity level of wastewater was established.Results:
There were differences in the number of diagnosis and treatment of patients, the amount of nuclide used and the amount of waste water produced in the nuclear medicine department at different medical institutions, so the evaluation and design of the intermittent decay pool were also different as a result . But the result should meet the relevant requirements of the standards GB 18871-2002 and HJ 1188-2021 the total activity discharged every month ≤10 ALImin, and the activity discharged once≤1 ALImin; gross alpha activity ≤1 Bq/L, gross β activity ≤10 Bq/L, 131I activity concentration ≤10 Bq/L; the temporary storage time after filled with radioactive wastewater ≥10 times longest half-life, and the temporary storage time of 131I in patient waste water ≥180 d.Conclusions:
The calculation method provided in this paper can be used to evaluate and design the volume of intermittent decay pool in nuclear medicine departments.