Five-year clinical outcomes of the second generation biodegradable polymer sirolimus-eluting stent (EXCROSSAL) in treating patients with de novo coronary lesions / 中华心血管病杂志
Chinese Journal of Cardiology ; (12): 121-127, 2021.
Article Dans Chinois | WPRIM | ID: wpr-941247
ABSTRACT

Objective:

To evaluate the five-year safety and efficacy of the second generation biodegradable polymer sirolimus-eluting stent (EXCROSSAL) in treating patients with de novo coronary artery diseases.

Methods:

Patients with coronary artery disease (CAD)who were implanted with EXTROSSAL stents in CREDIT Ⅱ and CREDIT Ⅲ study were included. CREDIT Ⅱ was a randomized trial, and CREDIT Ⅲ was a single-arm study. From November 2013 to December 2014, 833 CAD patients with de novo coronary lesions implanted with EXTROSSAL stents were selected from 33 centers in China. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularization. Secondary endpoints was patient-oriented composite endpoint (PoCE), including all-cause death, all myocardial infarction, or any revascularization within 5 years post stenting and stent thrombosis according to Academic Research Consortium's (ARC) definition. Kaplan Meier method was used to calculate the incidence of TLF and PoCE within 5 years after operation. Univariate Cox regression analysis was used to analyze the impacts of diabetes, small vessel disease (vessel diameter ≤ 2.74 mm), lesion length ≥ 16.7 mm and multivessel disease on the incidence of TLF within 5 years after operation.

Results:

A total of 833 patients were included in this study including 579 males (69.5%), the age was (59.3±9.1) years. And 832 (99.9%) patients completed 5-year clinical follow-up. The incidence of TLF and PoCE in the 5-year follow-up were 10.6%(86/811) and 15.5%(126/811), respectively. Stent thrombosis occurred in 1.0%(8/811) of patients. Univariate Cox regression analysis showed that vessel diameter ≤ 2.74 mm (HR=3.20,95%CI 1.90-5.39,P<0.001), lesion length ≥ 16.7 mm (HR=1.88,95%CI 1.18-2.99,P=0.007) and multivessel disease (HR=2.44,95%CI 1.60-3.72,P<0.001) were related factors of TLF within 5 years after operation.

Conclusion:

EXCROSSAL stent is effective and safe in treating CAD patients with de novo coronary lesions, with low incidence of TLF and PoCE within 5 years after operation.
Sujets)
Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Polymères / Facteurs temps / Maladie des artères coronaires / Agents cardiovasculaires / Chine / Facteurs de risque / Résultat thérapeutique / Sirolimus / Endoprothèses à élution de substances / Intervention coronarienne percutanée Type d'étude: Essai clinique contrôlé / Etude d'étiologie / Facteurs de risque Limites du sujet: Adulte très âgé / Humains / Mâle Pays comme sujet: Asie langue: Chinois Texte intégral: Chinese Journal of Cardiology Année: 2021 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) Sujet Principal: Polymères / Facteurs temps / Maladie des artères coronaires / Agents cardiovasculaires / Chine / Facteurs de risque / Résultat thérapeutique / Sirolimus / Endoprothèses à élution de substances / Intervention coronarienne percutanée Type d'étude: Essai clinique contrôlé / Etude d'étiologie / Facteurs de risque Limites du sujet: Adulte très âgé / Humains / Mâle Pays comme sujet: Asie langue: Chinois Texte intégral: Chinese Journal of Cardiology Année: 2021 Type: Article