Effect of circulating exosomes in patients with sepsis on T cell function / 中华危重病急救医学
Chinese Critical Care Medicine
; (12): 586-591, 2023.
Article
de Zh
| WPRIM
| ID: wpr-982637
Bibliothèque responsable:
WPRO
ABSTRACT
OBJECTIVE@#To investigate the effect of circulating exosomes (EXO) on T cell function in patients with sepsis.@*METHODS@#Plasma EXO were obtained by ultracentrifugation from 10 patients with sepsis admitted to the emergency intensive care unit of Guangdong Provincial People's Hospital Affiliated to Southern Medical University. Transmission electron microscopy observation, nanoparticle tracking analysis (NTA), and Western blotting were used to detect EXO markers to identify their characteristics. Furthermore, peripheral blood mononuclear cells (PBMC) were isolated from the peripheral blood of 5 healthy volunteers, primary T cells were sorted by magnetic beads and expanded in vitro. After 24 hours of intervention with different doses (0, 1, 2.5, 5, 10 mg/L) of circulating EXO in patients with sepsis, T-cell activity was assessed using a cell counting kit-8 (CCK-8). The expression of T cell activation indicators CD69 and CD25 were observed using flow cytometry. Additional evaluations were performed on immunosuppressive indicators including the expression of programmed cell death 1 (PD-1) in CD4+ T cells and the proportion of regulatory T cell (Treg).@*RESULTS@#The identification results confirmed that the successful isolation of EXO from the plasma of sepsis patients. The expression level of circulating EXO in sepsis patients was higher than that in healthy control group (mg/L: 48.78±5.14 vs. 22.18±2.25, P < 0.01). After 24 hours of intervention with 5 mg/L of plasma EXO from sepsis patients, T cells activity began to show suppression [(85.84±0.56)% vs. (100.00±0.00)%, P < 0.05]. As the dosage increased, after 24 hours of intervention with 10 mg/L of EXO, T cells activity was significantly suppressed [(72.44±2.36)% vs. (100.00±0.00)%, P < 0.01]. Compared with the healthy control group, after T cells intervention with plasma EXO from sepsis patients, the expression of early activation marker CD69 was significantly reduced [(52.87±1.29)% vs. (67.13±3.56)%, P < 0.05]. Meanwhile, there was an upregulation of PD-1 expression in T cells [(57.73±3.06)% vs. (32.07±0.22)%, P < 0.01] and an increase in the proportion of Treg [(54.67±1.19)% vs. (24.60±3.51)%, P < 0.01]. However, the expression of the late activation marker CD25 remained stable [(84.77±3.44)% vs. (85.93±2.32)%, P > 0.05].@*CONCLUSIONS@#Circulating EXO in sepsis patients induce T cell dysfunction, which may be a novel mechanism lead to immunosuppression in sepsis.
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Agranulocytes
/
Lymphocytes T régulateurs
/
Sepsie
/
Exosomes
/
Récepteur-1 de mort cellulaire programmée
Limites du sujet:
Humans
langue:
Zh
Texte intégral:
Chinese Critical Care Medicine
Année:
2023
Type:
Article