Determination of Hg in biological samples by inductively coupled plasma mass spectrometry / 法医学杂志
Journal of Forensic Medicine
;
(6): 193-195, 2011.
Article
Dans Chinois
| WPRIM
| ID: wpr-983650
ABSTRACT
OBJECTIVE@#To establish an inductively coupled plasma mass spectrometry (ICP-MS) method for determination of Hg in biological samples.@*METHODS@#The samples were digested with microwave digestion instrument. ICP-MS was applied to detect Hg in blood, urine and hair specimens by using 115In as an internal marker. The ability of gold to eliminate the memory effect of mercury was investigated with the gold amalgamate produced by gold and mercury.@*RESULTS@#The limits of detection were in the 0.01 microg/L, and the accuracy of the method ranged from 97.0% to 107.1%. The concentration of gold was 10 microg/L and the memory effect of mercury was resolved.@*CONCLUSION@#The method is accurate, rapid, sensitive and suitable for the cases of mercury poisoning and the clinical diagnosis and monitoring for patients with mercury poisoning.
Texte intégral:
Disponible
Indice:
WPRIM (Pacifique occidental)
Sujet Principal:
Normes de référence
/
Manipulation d'échantillons
/
Spectrométrie de masse
/
Reproductibilité des résultats
/
Sensibilité et spécificité
/
Toxicologie médicolégale
/
Poils
/
Indicateurs et réactifs
/
Mercure
/
Intoxication au mercure
Limites du sujet:
Humains
langue:
Chinois
Texte intégral:
Journal of Forensic Medicine
Année:
2011
Type:
Article
Documents relatifs à ce sujet
MEDLINE
...
LILACS