Analgesic effect and safety of using an epidural analgesia pump versus an intravenous analgesia pump for uterine artery embolization in the treatment of uterine fibroids / 中国基层医药
Chinese Journal of Primary Medicine and Pharmacy
; (12): 388-392, 2023.
Article
de Zh
| WPRIM
| ID: wpr-991760
Bibliothèque responsable:
WPRO
ABSTRACT
Objective:To investigate the analgesic effect and safety of using an epidural analgesia pump versus an intravenous analgesia pump for uterine artery embolization in the treatment of uterine fibroids. Methods:Fifty patients with uterine fibroids undergoing uterine artery embolization admitted to The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University from January 2019 to December 2021 were included in this study. They were divided into an observation group and a control group ( n = 25/group). Patients in the observation group used an epidural analgesia pump for pain relief, while patients in the control group used an intravenous analgesia pump for pain relief. At 1, 6, 12, and 24 hours after surgery, pain severity was compared between the two groups using the Visual Analogue Scale. Comfort level was compared between the two groups using the Bruggemann Comfort scale. Before and after surgery, respiratory rate, heart rate, blood pressure, and adverse reactions were compared between the two groups. Results:At 1 hour after surgery, the Visual Analogue Scale score in the observation group was significantly lower than that in the control group [3.00 (2.00, 5.50) vs. 7.00 (6.00, 8.00), Z = -3.84, P < 0.05]. At 6, 12, and 24 hours after surgery, there was a significant difference in the Visual Analogue Scale score between the two groups (all P > 0.05). Within 24 hours after surgery, the use of opioid analgesics in the observation group was less than that in the control group [16.00% (4/25) vs. 88.00% (22/25), χ2 = 25.96, P < 0.001]. At 1 hour after surgery, the Bruggemann Comfort Scale score in the observation group was significantly higher than that in the control group [0.00 (0.00, 0.50) vs. 0.00 (0.00, 0.00), Z = 2.08, P < 0.05]. At 6, 12, and 24 hours after surgery, there was no significant difference in the Bruggemann Comfort Scale score between the two groups (all P > 0.05). After surgery, heart rate was significantly decreased in each group compared with before surgery (both P < 0.05). There were no significant differences in respiratory rate and mean arterial pressure between the two groups before and after surgery (both P > 0.05). There were no significant differences in the incidences of postoperative nausea, vomiting, and fever between the two groups (all P > 0.05). Conclusion:The epidural analgesia pump used for uterine artery embolization in the treatment of uterine fibroids has a better analgesic effect and provides more comfort and is safer than the intravenous analgesia pump. The former is worthy of clinical promotion.
Texte intégral:
1
Indice:
WPRIM
langue:
Zh
Texte intégral:
Chinese Journal of Primary Medicine and Pharmacy
Année:
2023
Type:
Article